CZPT hydraulic replacement piston pump A10VO10
Brueninghaus Hydromatik CZPT A10VO pump
Collection 31 design: A10VO18, A10VO28, A10VO45, A10VO71, A10VO100, A10VO140
Series 32 design: A10VO45, A10VO71, A10VO100, A10VO140, A10VO180
Collection 52 & fifty three model: A10VO10, A10VO18, A10VO28, A10VO45, A10VO63, A10VO85
Description |
Open circuit
Management devices: DR, DRG, DFR, DFR1, DFLR, ED, FHD and EF.
Nominal strain 280 bars. Peak strain 350 bars.
– CZPT axial piston pump A10VO variable in swash plate design and style for hydrostatic transmissions in open up loop circuit
– Stream is proportional to travel pace and displacement, by adjusting the swash plate angle it is feasible to infinitely range the flow
– Mounting flange acc. to SAE J744
– Flanged ports acc. to SAE J518
– 2 scenario drain ports
– Excellent suction attributes
– Permissible doing work pressure 280 bar
– Minimal sound stage
– Extended service life
– Axial and radial loading of travel shaft feasible
– Large electrical power to fat ratio
– Wide assortment of controls
-Limited response times
Fluid
Prior to undertaking design and style, please see our data sheets RE 95710 (mineral oil ) and RE 95711 (ecologically suitable fluids) for comprehensive details on fluids and software situations. When using ecologically suitable fluids consideration have to be paid out to possible limitations of the complex information.
Notes on the variety of hydraulic fluid
In get to decide on the right fluid, it is essential to know the running temperature in the tank (open up circuit) in relation to the ambient temperature. The hydraulic fluid must be selected so that inside of the running temperature range, the viscosity lies inside of the the best possible variety (νopt.) see shaded area of the selection diagram. We advise that the increased viscosity grade is selected in every circumstance. Example: at an ambient temperature of X°C the functioning temperature in the tank is 60 °C. In the the best possible viscosity range νopt (shaded area), this corresponds to viscosity grades VG forty six or VG sixty eight, VG 68 must be chosen. Critical: The leakage oil temperature is affected by stress and speed and is usually higher than the tank temperature. Nonetheless max. temperature at any point in the method could not exceed 115 °C. At high temperatures you should use FKM seals.
DG – two stage, immediate control
The pump can be set to a minimum swivel angle by connecting an exterior switching pressure to port X. This will source the control piston immediately with handle oil a bare minimum force of fifty bar is necessary.
DR – Strain control
The strain manage serves to sustain a continual pressure in the hydraulic program, inside of the management range of the pump. The pump as a result supplies only the amount of hydraulic fluid needed by the actuators. Stress can be steplessly established at the pilot valve.
Technical Knowledge Brueninghaus Hydromatik CZPT A10VO
Desk of values (theoretical values, without effectiveness and tolerances values rounded)
CZPT A10VO | Displacement | Max Speed [rpm] | Stream | Weight |
cm three /r [ in three /r] | gpm [L/min] | kg [lbs] | ||
A10VO28DFR/31 | 28/1.seventy one | 3600 | 22.two/eighty four | 15/33 |
A10VO28DFR1/31 | 28/1.seventy one | 3600 | 22.two/eighty four | fifteen/33 |
A10VO28DR/31 | 28/1.71 | 3600 | 22.2/eighty four | fifteen/33 |
A10VO28DRG/31 | 28/1.71 | 3600 | 22.two/eighty four | fifteen/33 |
A10VO28DFLR/31 | 28/1.71 | 3600 | 22.2/84 | 15/33 |
A10VO28ED/31 | 28/one.71 | 3600 | 22.2/84 | fifteen/33 |
A10VO28FHD/31 | 28/one.71 | 3600 | 22.two/eighty four | fifteen/33 |
A10VO28EF/31 | 28/1.71 | 3600 | 22.two/eighty four | 15/33 |
A10VO45DFR/31 | forty five/two.seventy five | 3100 | 30.nine/117 | 21/46 |
A10VO45DFR1/31 | 45/two.75 | 3100 | thirty.nine/117 | 21/forty six |
A10VO45DR/31 | 45/2.seventy five | 3100 | 30.nine/117 | 21/forty six |
A10VO45DRG/31 | forty five/2.seventy five | 3100 | thirty.nine/117 | 21/forty six |
A10VO45DFLR/31 | forty five/2.75 | 3100 | thirty.9/117 | 21/46 |
A10VO45ED/31 | forty five/two.seventy five | 3100 | 30.9/117 | 21/forty six |
A10VO45FHD/31 | 45/2.75 | 3100 | 30.nine/117 | 21/forty six |
A10VO45EF/31 | 45/2.seventy five | 3100 | 30.nine/117 | 21/46 |
A10VO71DFR/31 | 71/four.33 | 2600 | 41.2/156 | 33/seventy three |
A10VO71DFR1/31 | seventy one/4.33 | 2600 | forty one.2/156 | 33/73 |
A10VO71DR/31 | seventy one/4.33 | 2600 | forty one.2/156 | 33/73 |
A10VO71DRG/31 | seventy one/four.33 | 2600 | 41.two/156 | 33/seventy three |
A10VO71DFLR/31 | 71/four.33 | 2600 | 41.2/156 | 33/73 |
A10VO71ED/31 | seventy one/4.33 | 2600 | forty one.two/156 | 33/73 |
A10VO71FHD/31 | seventy one/4.33 | 2600 | forty one.two/156 | 33/seventy three |
A10VO71EF/31 | 71/4.33 | 2600 | forty one.two/156 | 33/seventy three |
A10VO100DFR/31 | one hundred/6.one | 2400 | fifty two.eight/two hundred | forty five/ninety nine |
A10VO100DFR1/31 | one hundred/6.1 | 2400 | fifty two.8/two hundred | forty five/99 |
A10VO100DR/31 | a hundred/6.one | 2400 | 52.8/two hundred | forty five/ninety nine |
A10VO100DRG/31 | a hundred/six.1 | 2400 | 52.8/two hundred | 45/99 |
A10VO100DFLR/31 | 100/six.one | 2400 | 52.8/two hundred | 45/ninety nine |
A10VO100ED/31 | 100/6.1 | 2400 | fifty two.eight/200 | 45/ninety nine |
A10VO100FHD/31 | one hundred/six.1 | 2400 | 52.eight/two hundred | 45/ninety nine |
A10VO100EF/31 | a hundred/6.one | 2400 | 52.8/200 | 45/99 |
A10VO140DFR/31 | 140/eight.54 | 2100 | 22.2/84 | 60/132 |
A10VO140DFR1/31 | 140/eight.fifty four | 2100 | 22.two/84 | sixty/132 |
A10VO140DR/31 | 140/eight.fifty four | 2100 | 22.two/84 | sixty/132 |
A10VO140DRG/31 | 140/eight.54 | 2100 | 22.two/eighty four | 60/132 |
A10VO140DFLR/31 | a hundred and forty/eight.fifty four | 2100 | 22.two/eighty four | sixty/132 |
A10VO140ED/31 | one hundred forty/eight.fifty four | 2100 | 22.two/84 | sixty/132 |
A10VO140FHD/31 | 140/8.54 | 2100 | 22.two/84 | sixty/132 |
A10VO140EF/31 | a hundred and forty/8.fifty four | 2100 | 22.two/84 | 60/132 |