Rexroth Hydraulic Replacement Piston Pump A10vo10

Rexroth Hydraulic Replacement Piston Pump A10vo10

CZPT hydraulic replacement piston pump A10VO10

 
Brueninghaus Hydromatik CZPT A10VO pump
 
Collection 31 design: A10VO18, A10VO28, A10VO45, A10VO71, A10VO100, A10VO140
Series 32 design: A10VO45, A10VO71, A10VO100, A10VO140, A10VO180
Collection 52 & fifty three model: A10VO10, A10VO18, A10VO28, A10VO45, A10VO63, A10VO85

Description  

Open circuit
Management devices: DR, DRG, DFR, DFR1, DFLR, ED, FHD and EF.
Nominal strain 280 bars. Peak strain 350 bars.
 
– CZPT axial piston pump A10VO variable in swash plate design and style for hydrostatic transmissions in open up loop circuit
– Stream is proportional to travel pace and displacement, by adjusting the swash plate angle it is feasible to infinitely range the flow
– Mounting flange acc. to SAE J744
– Flanged ports acc. to SAE J518
– 2 scenario drain ports
– Excellent suction attributes
– Permissible doing work pressure 280 bar
– Minimal sound stage
– Extended service life
– Axial and radial loading of travel shaft feasible
– Large electrical power to fat ratio
– Wide assortment of controls
-Limited response times

Fluid
Prior to undertaking design and style, please see our data sheets RE 95710 (mineral oil ) and RE 95711 (ecologically suitable fluids) for comprehensive details on fluids and software situations. When using ecologically suitable fluids consideration have to be paid out to possible limitations of the complex information.
Notes on the variety of hydraulic fluid
In get to decide on the right fluid, it is essential to know the running temperature in the tank (open up circuit) in relation to the ambient temperature. The hydraulic fluid must be selected so that inside of the running temperature range, the viscosity lies inside of the the best possible variety (νopt.) see shaded area of the selection diagram. We advise that the increased viscosity grade is selected in every circumstance. Example: at an ambient temperature of X°C the functioning temperature in the tank is 60 °C. In the the best possible viscosity range νopt (shaded area), this corresponds to viscosity grades VG forty six or VG sixty eight, VG 68 must be chosen. Critical: The leakage oil  temperature is affected by stress and speed and is usually higher than the tank temperature. Nonetheless max. temperature at any point in the method could not exceed 115 °C. At high temperatures you should use FKM seals.
DG – two stage, immediate control
The pump can be set to a minimum swivel angle by connecting an exterior switching pressure to port X. This will source the control piston immediately with handle oil a bare minimum force of fifty bar is necessary.
DR – Strain control 
The strain manage serves to sustain a continual pressure in the hydraulic program, inside of the management range of the pump. The pump as a result supplies only the amount of hydraulic fluid needed by the actuators. Stress can be steplessly established at the pilot valve.

Technical Knowledge Brueninghaus Hydromatik CZPT A10VO
Desk of values (theoretical values, without effectiveness and tolerances values rounded)

CZPT A10VO Displacement Max Speed [rpm] Stream Weight
cm three /r [ in three /r] gpm [L/min] kg [lbs]
A10VO28DFR/31 28/1.seventy one 3600 22.two/eighty four 15/33
A10VO28DFR1/31 28/1.seventy one 3600 22.two/eighty four fifteen/33
A10VO28DR/31 28/1.71 3600 22.2/eighty four fifteen/33
A10VO28DRG/31 28/1.71 3600 22.two/eighty four fifteen/33
A10VO28DFLR/31 28/1.71 3600 22.2/84 15/33
A10VO28ED/31 28/one.71 3600 22.2/84 fifteen/33
A10VO28FHD/31 28/one.71 3600 22.two/eighty four fifteen/33
A10VO28EF/31 28/1.71 3600 22.two/eighty four 15/33
A10VO45DFR/31 forty five/two.seventy five 3100 30.nine/117 21/46
A10VO45DFR1/31 45/two.75 3100 thirty.nine/117 21/forty six
A10VO45DR/31 45/2.seventy five 3100 30.nine/117 21/forty six
A10VO45DRG/31 forty five/2.seventy five 3100 thirty.nine/117 21/forty six
A10VO45DFLR/31 forty five/2.75 3100 thirty.9/117 21/46
A10VO45ED/31 forty five/two.seventy five 3100 30.9/117 21/forty six
A10VO45FHD/31 45/2.75 3100 30.nine/117 21/forty six
A10VO45EF/31 45/2.seventy five 3100 30.nine/117 21/46
A10VO71DFR/31 71/four.33 2600 41.2/156 33/seventy three
A10VO71DFR1/31 seventy one/4.33 2600 forty one.2/156 33/73
A10VO71DR/31 seventy one/4.33 2600 forty one.2/156 33/73
A10VO71DRG/31 seventy one/four.33 2600 41.two/156 33/seventy three
A10VO71DFLR/31 71/four.33 2600 41.2/156 33/73
A10VO71ED/31 seventy one/4.33 2600 forty one.two/156 33/73
A10VO71FHD/31 seventy one/4.33 2600 forty one.two/156 33/seventy three
A10VO71EF/31 71/4.33 2600 forty one.two/156 33/seventy three
A10VO100DFR/31 one hundred/6.one 2400 fifty two.eight/two hundred forty five/ninety nine
A10VO100DFR1/31 one hundred/6.1 2400 fifty two.8/two hundred forty five/99
A10VO100DR/31 a hundred/6.one 2400 52.8/two hundred forty five/ninety nine
A10VO100DRG/31 a hundred/six.1 2400 52.8/two hundred 45/99
A10VO100DFLR/31 100/six.one 2400 52.8/two hundred 45/ninety nine
A10VO100ED/31 100/6.1 2400 fifty two.eight/200 45/ninety nine
A10VO100FHD/31 one hundred/six.1 2400 52.eight/two hundred 45/ninety nine
A10VO100EF/31 a hundred/6.one 2400 52.8/200 45/99
A10VO140DFR/31 140/eight.54 2100 22.2/84 60/132
A10VO140DFR1/31 140/eight.fifty four 2100 22.two/84 sixty/132
A10VO140DR/31 140/eight.fifty four 2100 22.two/84 sixty/132
A10VO140DRG/31 140/eight.54 2100 22.two/eighty four 60/132
A10VO140DFLR/31 a hundred and forty/eight.fifty four 2100 22.two/eighty four sixty/132
A10VO140ED/31 one hundred forty/eight.fifty four 2100 22.two/84 sixty/132
A10VO140FHD/31 140/8.54 2100 22.two/84 sixty/132
A10VO140EF/31 a hundred and forty/8.fifty four 2100 22.two/84 60/132

 

Rexroth Hydraulic Replacement Piston Pump A10vo10