Rexroth Hydraulic Motor A2fe28 32 45 with Low Price for Sale

Rexroth Hydraulic Motor A2fe28 32 45 with Low Price for Sale

CZPT hydraulic motor A2FE28/32/45 with Low Price for sale

A2FE180 hydraulic motor new manufacturer produced in Germany
 
CZPT fastened motor A2FE28, A2FE32, A2FE45, A2FE56, A2FE63, A2FE80, A2FE90, A2FE107, A2FE125, A2FE160, A2FE180,
A2FE250, A2FE355

Description  

Open and shut circuits
Collection sixty one and sixty
Stress:
Measurement 28 to180 Nominal stress 5800 psi (400 bar)/ Peak strain 6500 psi (450 bar)
Size 250 to 355 Nominal force 5100 psi (350 bar)/ Peak strain 5800 psi (four hundred bar)
 
The A2FE fastened plug-in motor with axial tapered piston rotary group of bent-axis design and style, for hydrostatic drives in open up and closed circuits
-Much-reaching integration in mechanical gearbox because of to recessed mounting flange located in the centre of the circumstance (very room-conserving construction)
-The output pace is dependent on the stream of the pump and the displacement of the motor.
-The output torque will increase with the force differential between the higher-pressure and the minimal-strain facet.
-Tiny dimensions.
-High whole effectiveness.
-Complete unit, all set-assembled and examined.
-Straightforward to put in, basically plug into the mechanical gearbox.
-No configuration requirements to be noticed when putting in.
 
Technological Data 
Desk of values (theoretical values, with no effectiveness and tolerances values rounded)

CZPT A2FE motor A2FE28 A2FE32 A2FE45 A2FE56 A2FE63 A2FE80  
Displacement Vg cm3 28.1 32 forty five.six fifty six.one sixty three 80.4  
Pace greatest nnom rpm 6300 6300 5600 5000 5000 4500  
nmax2) rpm 6900 6900 6200 5500 5500 5000  
Input flow Vg qV L/min 177 202 255 281 315 362  
Torque at Vg and Dp = 350 bar T Nm 157 178 254 313 351  
Dp = 400 bar T Nm 179 204 290 357 401  
Rotary stiffness c kNm/ rad 2.93 3.12 four.18 five.ninety four six.twenty five eight.seventy three  
Second of inertia JGR  kgm2 .0012 .0012 .0571 .0042 .0042 .0072  
Optimum angular a rad/s2 6500 6500 14600 7500 7500 6000  
Case quantity V  L .2 .2 .33 .forty five .45 .fifty five  
Mass (approx.) m kg 10.five ten.five 15 eighteen 19 23  
Size A2FE90 A2FE107 A2FE125 A2FE160 A2FE180 A2FE250 A2FE355
Displacement Vg cm3 ninety 106.7 125 160.four a hundred and eighty 250 355
Pace maximum nnom rpm 4500 4000 4000 3600 3600 2700 2240
nmax2) rpm 5000 4400 4400 4000 4000
Input movement qV L/min 405 427 500 577 648 675 795
Torque at Vg Dp = 350 bar T 501 594 696 893 1003 1393 1978
Dp = four hundred bar T 573 679 796 1571 1146
Rotary stiffness c kNm/rad nine.fourteen 11.two eleven.nine seventeen.four eighteen.two seventy three.1 ninety six.1
Instant of inertia JGR kgm2 .0072 .0116 .0116 .571 .571 .061 .102
Optimum angular a rad/s2 6000 4500 4500 3500 3500 ten thousand 8300
Situation quantity V L .55 .8 .eight one.1 one.1 two.5 3.five
Mass (approx.) m kg 25 34 36 47 forty eight 82 110

CZPT fluid
Prior to beginning task plHangCZPT, you should refer to our information sheets RE 95710 (mineral oil), RE 95711 (environmentally suitable hydraulic fluids) and RE 95712 (HFD hydraulic fluids) and RE 95713 (HFA, HFB, HFC hydraulic fluids) for comprehensive data concerning the decision of hydraulic fluid and application situations. The plug-in motor A2FE is not suited for procedure with HFA hydraulic fluid. If HFB, HFC or HFD or environmentally acceptable hydraulic fluids are utilized, the constraints regarding technical info or other seals must be observed.
Information concerning the selection of hydraulic fluid
The appropriate selection of hydraulic fluid calls for knowledge of the operating temperature in relation to the ambient temperature: in a closed circuit, the circuit temperature, in an open up circuit, the reservoir temperature. The hydraulic fluid must be picked so that the running viscosity in the functioning temperature range is inside of the optimum variety (νopt), see shaded spot of the variety diagram. We suggested that the greater viscosity class be picked in every single circumstance. Illustration: At an ambient temperature of X °C, an working temperature of 60 °C is set in the circuit. In the optimum working viscosity variety (νopt., shaded region) this corresponds to the viscosity courses VG forty six or VG sixty eight to be selected: VG 68.
Be aware: The scenario drain temperature, which is afflicted by pressure and speed, can be larger than the circuit temperature or reservoir temperature. At no level of the component could the temperature be higher than a hundred and fifteen °C. The temperature variation specified under is to be taken into account when determining the viscosity in the bearing. If the earlier mentioned situations can’t be preserved because of to intense running parameters, we suggest the use of a flushing and boost stress valve.
Shaft seal
Permissible force loading the support existence of the shaft seal is motivated by the velocity of the axial piston unit and the situation drain strain (situation force). The imply differential force of 2 bar amongst the circumstance and the ambient stress may possibly not be enduringly exceeded at normal running temperature. For a larger differential stress at diminished velocity, see diagram. Momentary force spikes (t < 0.1 s) of up to 10 bar are permitted. The service life of the shaft seal decreases with an increase in the frequency of pressure spikes.

 